Published · By EVMotorMagnets engineering content team · Engineering method reviewed · Next planned source review 2027-02-07
Decision guide: what to specify before ordering
The checker answers a narrow question: how an arc is sized, and how far a fixed chordal magnetization direction departs from the local tangent. Use the following evidence and limits to turn that result into a supplier discussion.
1. Resolve the direction first
Draw a fixed chordal arrow or a continuously turning tangent field. An anisotropic easy axis and the final magnetizing fixture must be compatible. [S2]
2. Keep geometry separate from performance
The checker derives dimensions and ideal vector projections. The equations and reproducible examples below do not predict flux, torque or motor efficiency.
Inspect the derivation3. Model the complete array
Halbach field depends on pole number, magnet thickness and surrounding iron. A tangential transition segment alone does not define gain or back-iron removal. [S1]
Orientation: tangential, chordal and radial are different drawings
“Through circumference” can mean a tangent that turns continuously with position, a single fixed vector connecting the arc ends, or a multipole sequence. Mark the reference center, viewing direction, N/S ends and magnetization arrows. A radial vector points through the wall; a chordal vector matches the tangent only at the arc midpoint. The diagram is schematic. K&J’s catalog uses the circumferential label for parallel magnetization lines, so the label alone does not specify a continuously curved vector. [S6]
Keep the orientation of the material separate from the direction of the field used for final magnetization. Preferred-direction behavior is described in the material background. [S2]
Compare topology requirements before choosing a material
| Topology | Specify on the drawing | Decision still open |
|---|---|---|
| Chordal arc | One fixed direction and angular tolerance | Whether the local direction error meets the application |
| Halbach transition | Every segment vector and full ring sequence | Working-side field and residual external field |
| Spoke concentrator | Magnet faces, steel poles, hub and bridges | Leakage and nonlinear steel saturation |
| Multipole segment | Pole pitch, vector pattern and sensor stand-off | Fixture capability and measured waveform |
| Continuously curved arc | Local tangent direction versus position | Compatible easy-axis process and fixture feasibility |
These are engineering review prompts. Full-machine Halbach analysis is supported by [S1]; orientation constraints by [S2]. No universal concentration ratio is assigned here.
Material family does not establish orientation capability
| Material class | Evidence to request | Alternative to compare |
|---|---|---|
| Sintered NdFeB | Grade, easy-axis pattern, curves at temperature and coating | Several separately oriented segments |
| Bonded NdFeB | Actual compound, orientation, binder and magnetization limits | Sintered segments if the required field is not met |
| SmCo | Specific grade curves, machining and assembly constraints | Compare total process and retention requirements |
| Ferrite | Isotropic/anisotropic grade and compatible vector pattern | Change the circuit or pole geometry if needed |
The distinction between isotropic and anisotropic behavior matters more than the word “bonded” or “ferrite” alone. Confirm the actual grade and processing route with the supplier. A specially shaped pulse fixture does not by itself demonstrate a curved easy-axis pattern. [S2]
Reproduce the geometry and angular comparison
Ro = OD/2; Ri = ID/2; Rm = (Ro + Ri)/2; t = Ro − Ri
θ = span in degrees × π/180; mean arc = Rm × θ
Outer chord = 2 × Ro × sin(θ/2); end-face area = t × axial length
Maximum chordal direction error = span/2
Mean projection = sin(θ/2)/(θ/2); tip projection = cos(θ/2)
These geometric derivations assume concentric circular arcs and radial end faces. Parallel-sided, eccentric or chamfered parts require a separate drawing and are outside this area calculation. For a fixed unit magnetization vector, its local tangent component is cos(φ), where φ runs from −θ/2 to θ/2. Averaging this over the arc gives sin(θ/2)/(θ/2). The displayed reductions are 100 times one minus the respective projection. This idealization assumes uniform magnitude and does not solve a field boundary-value problem.
| Span | Tip direction error | Mean projection reduction | Tip projection reduction |
|---|---|---|---|
| 25° | 12.5° | 0.79% | 2.37% |
| 35° | 17.5° | 1.55% | 4.63% |
| 45° | 22.5° | 2.55% | 7.61% |
| 55° | 27.5° | 3.80% | 11.30% |
| 90° | 45° | 9.97% | 29.29% |
The 35° and 55° bands used in tool guidance are editorial prompts to compare alternatives. They are not published material limits. A 35° span has about 1.55% mean reduction but 4.63% tip reduction; conflating the two understates the local deviation. Neither number is a measured air-gap flux loss.
Halbach: use the transition arc as one part of an array
Xia, Zhu and Howe model the complete machine in polar coordinates, including recoil permeability. Their analysis compares predictions with finite-element analysis and measurements, and identifies dependence on pole number and magnet thickness. The result does not support assigning a fixed 1.35× gain to one tangential arc. [S1]
For your next review, provide ring radii, vector sequence, segment gaps, air gap and iron geometry. Compare working-side field and external field in the assembled model before changing the back iron or mechanical retention. This is a proposed evaluation workflow, not a performance claim.
Spoke: treat area concentration as a circuit question
The sketch illustrates adjacent tangential magnets feeding a common steel pole. A useful design review must include the working pole area, magnet area, hub and bridge paths and nonlinear steel data. This page has no specified pole width, steel curve or air gap, so concentration remains unknown.
Compare a model with actual bridges and shaft against an idealized model without those paths. Record where flux is diverted and whether local saturation changes the result. This comparison is a suggested method; no universal leakage percentage or steel saturation threshold is asserted.
Load line and temperature: why the checker leaves performance unknown
Remanence, intrinsic coercivity, curve shape and temperature are distinct inputs to magnet selection. A magnetic operating point depends on the circuit load line as well as the material curve. An arc-length-to-area ratio alone does not establish a thermal safety percentage. [S3]
| Quantity | Status | Minimum additional evidence |
|---|---|---|
| Arc/chord/wall/end-face area | Calculated geometry | Dimensioned drawing and agreed tolerances for production |
| Requested Br and temperature | User request only | Specific grade and Br reference temperature |
| Permeance coefficient and field | Unknown; not calculated | Full circuit, air gap, material curves and field model |
| Demagnetization margin | Unknown; not calculated | Grade curves at temperature and worst reverse-field load case |
| Assembly force and retention | Unknown; not calculated | Gap-dependent field/force model and structural load cases |
Changing requested Br or temperature records a different inquiry requirement; it intentionally does not alter the geometric projections. The exporter preserves this distinction so an unknown magnetic rating cannot become a purchase specification.
Assembly and retention: define the missing load cases
Like-facing pole regions can repel; other relative orientations can attract. Peak force depends on position, gap and the surrounding array. The conceptual force arrows below are not force measurements. Do not select a jig, adhesive joint or retaining sleeve from Br and face area alone.
Before a retention decision, request a review of speed, segment mass, radius, load path, thermal expansion, fit, fatigue and overspeed conditions. Adhesive selection also needs substrate, coating, surface preparation, bondline, cure and environment. This page supplies no universal speed threshold, sleeve thickness, preload or adhesive shear-strength matrix.
Agree an inspection plan with separate measurement targets
| Measurement | Reference / status | What must be agreed |
|---|---|---|
| Permanent-magnet material properties | IEC 60404-5:2015 catalog scope [S4] | Test conditions and required material properties |
| Magnetic dipole moment | IEC 60404-14:2002 catalog scope [S5] | Specimen, coil calibration, orientation and uncertainty |
| Local tangential/radial field scan | Application-specific plan | Probe axes, stand-off, grid, temperature and limits |
| Assembled waveform / harmonics | Application-specific plan | Rotor position, sensor setup, harmonic definition and limits |
Part 5 concerns material measurements; Part 14 concerns dipole-moment measurement by withdrawal or rotation. Neither public catalog scope establishes a universal 1.5° vector-tilt criterion or a Hall-scan acceptance band. [S4] [S5]
For the illustrated application scan, record both the normal and tangential components at agreed positions. A normal-only reading cannot characterize the tangential vector; it also need not be zero. Archive raw readings and the fixture drawing alongside the agreed acceptance rules.
Three reproducible examples, not measured customer cases
All examples assume a uniform fixed chordal direction. They demonstrate only the equations above. There are no claimed dynamometer results, customer deployments or qualified material ratings.

Narrow span
OD/ID 36/30 mm, span 25°, axial length 15 mm.
Mean arc 7.20 mm; tip direction error 12.5°; mean projection reduction 0.79%.
Compare the resulting local direction error with the drawing tolerance.
Moderate span
OD/ID 100/80 mm, span 45°, axial length 30 mm.
Mean arc 35.34 mm; tip direction error 22.5°; mean projection reduction 2.55%.
Model the circuit if field uniformity at the tips matters.
Wide span
OD/ID 100/80 mm, span 90°, axial length 30 mm.
Mean arc 70.69 mm; tip direction error 45°; mean projection reduction 9.97%.
Compare subdivision into smaller arcs, including extra joints and tolerances.
Sourcing: make the quote comparable
Use the exported brief as an inquiry draft. Attach a drawing revision and ask suppliers to distinguish machining, alignment tooling, magnetizing fixtures, coating, inspection and packaging. Request one-time and recurring costs separately, with quantity, validity date, prototype acceptance and lead-time assumptions.
Tooling cost, MOQ and delivery are unknown until quoted. A fixed chordal option and an assembly of smaller segments are alternatives to compare when custom orientation is unconfirmed. The lower projection error of smaller segments must be weighed against extra handling, joints and tolerance stack-up.
Risk and decision matrix
| Risk | Decision consequence | Minimum next action |
|---|---|---|
| Misuse: projection treated as efficiency | Wrong motor target or misleading purchasing specification | Keep geometric results separate; validate the assembled field/torque model |
| Scenario mismatch: incompatible easy axis | Requested vector pattern cannot be produced as drawn | Get written orientation-process confirmation or compare segmented construction |
| Thermal assumption from material family | Unqualified grade or reverse-field operating point | Obtain grade curves at temperature and analyze the actual load case |
| Cost: custom fixture omitted | Incomplete unit-price comparison and schedule | Request dated tooling, MOQ, inspection and prototype terms |
| Retention chosen from generic values | Unverified mechanical assembly | Review actual forces, fit and thermal/mechanical load cases |
| Inspection axes or stand-off unspecified | Conflicting measurements and acceptance disputes | Approve a common fixture and measurement procedure before production |
FAQs for specification, validation and sourcing
Direction and geometry
What does magnetized through circumference mean?
The intended magnetization runs tangentially around an arc. Specify whether this means a continuously turning local direction, a fixed chordal direction, or a sequence of discrete vectors; the phrase alone is insufficient for manufacturing.
How does chordal parallel magnetization differ from curved alignment?
Chordal magnetization has one fixed direction parallel to the end-to-end chord. It matches the local tangent at the arc midpoint; direction error grows to half the arc span at each tip. Curved alignment follows the local tangent throughout.
Is the projection reduction a motor efficiency loss?
No. The mean reduction is 100 × [1 − sin(θ/2)/(θ/2)] with θ in radians. It averages a unit vector projection over the arc. Edge reduction is 100 × [1 − cos(θ/2)]. Neither includes the magnetic circuit, leakage, saturation or electrical losses.
Is there a universal maximum chordal arc angle?
No universal performance limit is established here. The tool uses 35° and 55° only as comparison bands. Use local direction tolerance and full-circuit field analysis to decide whether a larger span or several smaller segments meets the application.
Can a curved magnetizing fixture reorient any sintered magnet?
Do not assume it can. An anisotropic material has a preferred magnetic direction established in its processing. The supplier must confirm an easy-axis pattern compatible with the drawing; a different final magnetizing fixture alone does not establish that capability.
Are all bonded or ferrite magnets isotropic?
No. Material family alone does not identify the orientation. Specify the actual compound and whether it is isotropic or anisotropic, then confirm that its magnetization pattern and pulse fixture are compatible.
Array performance and testing
Can this tool predict Halbach flux gain?
No. Pole number, radii, magnet thickness, recoil permeability, segmentation, air gap and surrounding iron affect the complete array. The Halbach research linked in the report compares complete field models with FEA and measurements, rather than assigning a fixed gain to one arc.
What does a spoke flux concentrator require?
Tangentially magnetized pieces can feed a common steel pole. Evaluate magnet-face area, working pole area, bridge and hub leakage, steel B–H data and air gap in the complete rotor. This tool supplies geometry, not a concentration ratio.
Does rotor pole count mean number of magnet segments?
No. Rotor poles describe the full magnetic pattern. One pole may use multiple segments. State segments per pole, their orientation sequence, gaps and ring coverage separately in the drawing.
Why is no demagnetization safety percentage shown?
Temperature and material family do not determine a safety percentage. Grade-specific demagnetization curves at temperature and the worst reverse field are required. Br alone does not establish coercivity or irreversible loss.
How should circumferential magnetization be inspected?
Agree the probe axes, location, stand-off, scan path, temperature, calibration and acceptance limits with the supplier. A normal-component scan on the curved face alone does not characterize the tangential vector. Dipole moment and local surface field are different measurements.
What do IEC 60404-5 and IEC 60404-14 cover?
The cited 2015 edition of Part 5 addresses permanent-magnet material property measurements. The cited 2002 edition of Part 14 addresses magnetic dipole moment by withdrawal or rotation. These catalog scopes do not set a universal application-specific vector tilt or waveform acceptance limit.
Assembly and inquiry
Can I size an adhesive joint or retaining sleeve from this tool?
No. Required inputs include speed, radius, mass, load path, fit, thermal expansion, fatigue and verified joint properties. Request structural analysis and prototype validation before selecting adhesive, sleeve thickness or preload.
Are tooling prices, MOQ and lead time fixed?
No price or delivery commitment is established by this page. Ask the supplier to separate cutting, coating, alignment tooling, magnetizing fixtures, inspection and packaging in a dated quote tied to drawing revision and quantity.
What should I do if the geometry is unknown?
Use an illustrative preset to understand the fields, then send a drawing or application sketch through the contact link. Presets and worked examples are learning inputs, not qualified products or measured customer results.
What does the RFQ export include?
It includes requested dimensions, topology, material, Br and temperature plus explicitly idealized chordal comparisons. Unverified magnetic performance, tolerances, coating, retention, commercial terms and shipping classification remain open for agreement.
Review brief checklist and next action
- Confirm OD, ID, axial length, span, dimensional tolerances and reference view.
- Add local magnetization arrows, N/S markings, rotor poles, segments per pole and gaps.
- Request specific grade, Br reference temperature, thermal curves and application field review.
- Agree local scan and/or dipole-moment acceptance, coating, retention and handling requirements.
- Add drawing revision, quantity, sample acceptance, dated commercial terms and shipping review.
If dimensions are missing, send an application sketch for review. For the distinct task of interpreting a field profile, see the circumferential magnetic-field guide or field-diagram reference.
Sources, method and limits
Sources checked 2026-11-07. Publication years below describe the cited editions, not a claim that every standard is the latest contractual edition. Agree the applicable edition and licensed test method with your laboratory. Equations, comparison bands, worked examples and review checklists are this page’s own geometry derivations or proposed workflow, as identified above.
- [S1] Xia, Zhu & Howe (2004), Analytical Magnetic Field Analysis of Halbach Magnetized Permanent-Magnet Machines
IEEE Transactions on Magnetics 40, 1864–1872. DOI: 10.1109/TMAG.2004.828933. Complete-machine field models, FEA and measurements; not a fixed segment gain.
- [S2] Arnold Magnetic Technologies, The Elements of Magnetics (2013)
Background on preferred magnetization directions and material processing. Does not establish custom curved-alignment capability for a supplier.
- [S3] Arnold Magnetic Technologies, Magnet FAQs (2013)
Br, coercivity, temperature and load-line concepts. Not qualification of these presets or an adhesive/retention specification.
- [S4] IEC 60404-5:2015 — permanent-magnet material measurement methods
Public catalog scope: material properties and demagnetization curves. This page does not claim access to all normative clauses or prescribe standard acceptance limits.
- [S5] IEC 60404-14:2002 — magnetic dipole moment measurement
Public catalog scope: withdrawal or rotation with a detection coil. Does not certify a local surface Hall scan or an automotive vector-tilt tolerance.
- [S6] K&J Magnetics, Magnetization Directions — Arc Segments
Undated supplier documentation, checked 2026-11-07. The circumferential catalog label describes parallel directions, not vectors curving around the arc. No capability or stock claim for EVMotorMagnets follows.
Use this page for geometry comparison and preparing a review brief. Magnetic performance, thermal margin, mechanical retention and manufacturing capability remain unqualified until the complete application is modeled and tested. No measured customer cases, adhesive properties, supplier prices or delivery commitments are established here.