Geometry checker + engineering decision guide

Arc Magnets Magnetized Through Circumference

“Through circumference” can describe a fixed direction between an arc’s ends. Check geometry and ideal chordal direction error, then export a supplier review brief.

Enter your arc geometry

Concentric arc with radial end faces only. All fields required. Dimensions 0.1–2000 mm; OD > ID, wall ≥ 0.01 mm. Span 0.1–180°; poles even, 2–200; Br 0.2–1.6 T; temperature −60–350°C. Br and temperature record requested values only. These bounds describe this checker, not manufacturing or material ratings.

Topology candidate — full rotor model required

A segment drawing cannot establish array gain, waveform, load line, or thermal margin. The angular comparison below is a hypothetical chordal alternative, not the selected magnetization pattern.

Mean-radius arc
9.42 mm
Outer-radius chord
10.14 mm
Radial wall
4.00 mm
End-face area
100.00 mm²
Max chordal direction error
11.25°
Ideal mean projection reduction
0.64%

Ideal edge projection reduction: 1.92%. For non-chordal selections these angles and projections describe a hypothetical chordal alternative only.

Visual: chordal direction versus local tangent
Diagram 4: Chordal Parallel Approximation ErrorMaximum edge angular error Δθ = θ_arc / 2 and transverse flux leakage
Chord Line Magnetization Vector (M_chord)Midpoint: Δθ = 0° (Perfect Alignment)Δθ = θ/2Δθ = θ/2Tip direction error = half the arc span

Known geometry / unknown performance

  • Concentric annular sector with radial end faces only; parallel-sided / eccentric arcs need a separate drawing. The 35° / 55° labels are editorial comparison bands, not material limits or qualification criteria.
  • Pc, air-gap/end-face field, assembly force and demagnetization margin: unknown. Require the full circuit, air gap, grade-specific B–H curves at temperature, reverse field and assembly geometry.
  • Br 1.42 T and 80.0°C are requested specification values only; they do not change this geometry calculation or certify grade availability.
  • Rotor poles describe the complete rotor. Segments per pole and ring coverage must be specified separately; this tool does not check packing.

Tradeoffs and next steps

  • Chordal alignment simplifies the orientation drawing but departs from the local tangent toward the tips.
  • Additional segments can reduce ideal direction error, while adding joints, tolerance stack-up and assembly work.
  • Attach a dimensioned drawing with N/S polarity, view direction and magnetization arrows; agree orientation capability with the supplier.
  • Request grade curves at the intended temperature and validate the complete rotor/coupler under worst-case reverse field.
  • Copy or download the review brief below; add tolerances, quantity and acceptance criteria before requesting a quote.

Export a draft for engineering review

Commercial terms and acceptance limits remain open for agreement. No response-time commitment is implied.

Preview / manually copy review brief

Published · By EVMotorMagnets engineering content team · Engineering method reviewed · Next planned source review 2027-02-07

Decision guide: what to specify before ordering

The checker answers a narrow question: how an arc is sized, and how far a fixed chordal magnetization direction departs from the local tangent. Use the following evidence and limits to turn that result into a supplier discussion.

1. Resolve the direction first

Draw a fixed chordal arrow or a continuously turning tangent field. An anisotropic easy axis and the final magnetizing fixture must be compatible. [S2]

2. Keep geometry separate from performance

The checker derives dimensions and ideal vector projections. The equations and reproducible examples below do not predict flux, torque or motor efficiency.

Inspect the derivation

3. Model the complete array

Halbach field depends on pole number, magnet thickness and surrounding iron. A tangential transition segment alone does not define gain or back-iron removal. [S1]

4. Qualify material and measurement

Request temperature-dependent grade curves, then agree separate material, dipole-moment and local-field inspections. Br alone is insufficient. [S3] [S4] [S5]

Orientation: tangential, chordal and radial are different drawings

“Through circumference” can mean a tangent that turns continuously with position, a single fixed vector connecting the arc ends, or a multipole sequence. Mark the reference center, viewing direction, N/S ends and magnetization arrows. A radial vector points through the wall; a chordal vector matches the tangent only at the arc midpoint. The diagram is schematic. K&J’s catalog uses the circumferential label for parallel magnetization lines, so the label alone does not specify a continuously curved vector. [S6]

Diagram 1: Magnetic Vector Orientation ComparisonThrough-Thickness (Radial) vs Circumferential (Tangential)
A. Standard Radial (Through-Thickness)NORTH FACE (Convex OD)SOUTH FACE (Concave ID)Magnetic path length Lm = Thickness TB. Magnetized Through CircumferenceSNFlux travels azimuthally along arc spanMagnetic path length Lm ≈ Arc Length L_arc

Keep the orientation of the material separate from the direction of the field used for final magnetization. Preferred-direction behavior is described in the material background. [S2]

Compare topology requirements before choosing a material

Table 1. Review questions for each topology; no gain or manufacturing availability is implied.
TopologySpecify on the drawingDecision still open
Chordal arcOne fixed direction and angular toleranceWhether the local direction error meets the application
Halbach transitionEvery segment vector and full ring sequenceWorking-side field and residual external field
Spoke concentratorMagnet faces, steel poles, hub and bridgesLeakage and nonlinear steel saturation
Multipole segmentPole pitch, vector pattern and sensor stand-offFixture capability and measured waveform
Continuously curved arcLocal tangent direction versus positionCompatible easy-axis process and fixture feasibility

These are engineering review prompts. Full-machine Halbach analysis is supported by [S1]; orientation constraints by [S2]. No universal concentration ratio is assigned here.

Material family does not establish orientation capability

Table 2. Supplier information to request; all grades and limits remain unqualified.
Material classEvidence to requestAlternative to compare
Sintered NdFeBGrade, easy-axis pattern, curves at temperature and coatingSeveral separately oriented segments
Bonded NdFeBActual compound, orientation, binder and magnetization limitsSintered segments if the required field is not met
SmCoSpecific grade curves, machining and assembly constraintsCompare total process and retention requirements
FerriteIsotropic/anisotropic grade and compatible vector patternChange the circuit or pole geometry if needed

The distinction between isotropic and anisotropic behavior matters more than the word “bonded” or “ferrite” alone. Confirm the actual grade and processing route with the supplier. A specially shaped pulse fixture does not by itself demonstrate a curved easy-axis pattern. [S2]

Diagram 7: Sintered Magnetic Alignment Pressing ToolingConceptual alignment processes; supplier capability unconfirmed
A. Standard Linear Parallel PressingFixed-direction alignment conceptProduces Chordal Parallel AlignmentB. Curved alignment conceptCustom process: supplier reviewConfirm easy-axis capability first

Reproduce the geometry and angular comparison

Ro = OD/2; Ri = ID/2; Rm = (Ro + Ri)/2; t = Ro − Ri

θ = span in degrees × π/180; mean arc = Rm × θ

Outer chord = 2 × Ro × sin(θ/2); end-face area = t × axial length

Maximum chordal direction error = span/2

Mean projection = sin(θ/2)/(θ/2); tip projection = cos(θ/2)

These geometric derivations assume concentric circular arcs and radial end faces. Parallel-sided, eccentric or chamfered parts require a separate drawing and are outside this area calculation. For a fixed unit magnetization vector, its local tangent component is cos(φ), where φ runs from −θ/2 to θ/2. Averaging this over the arc gives sin(θ/2)/(θ/2). The displayed reductions are 100 times one minus the respective projection. This idealization assumes uniform magnitude and does not solve a field boundary-value problem.

Diagram 4: Chordal Parallel Approximation ErrorMaximum edge angular error Δθ = θ_arc / 2 and transverse flux leakage
Chord Line Magnetization Vector (M_chord)Midpoint: Δθ = 0° (Perfect Alignment)Δθ = θ/2Δθ = θ/2Tip direction error = half the arc span
Table 3. Ideal chordal comparison, calculated directly from the equations above.
SpanTip direction errorMean projection reductionTip projection reduction
25°12.5°0.79%2.37%
35°17.5°1.55%4.63%
45°22.5°2.55%7.61%
55°27.5°3.80%11.30%
90°45°9.97%29.29%

The 35° and 55° bands used in tool guidance are editorial prompts to compare alternatives. They are not published material limits. A 35° span has about 1.55% mean reduction but 4.63% tip reduction; conflating the two understates the local deviation. Neither number is a measured air-gap flux loss.

Halbach: use the transition arc as one part of an array

Xia, Zhu and Howe model the complete machine in polar coordinates, including recoil permeability. Their analysis compares predictions with finite-element analysis and measurements, and identifies dependence on pole number and magnet thickness. The result does not support assigning a fixed 1.35× gain to one tangential arc. [S1]

Diagram 2: Halbach Array 90° Azimuthal TransitionConceptual vector sequence; assembled field needs validation
Main Pole (S)Circumferential Arc90° AzimuthalMain Pole (N)Circumferential Arc90° AzimuthalMain Pole (S)WORKING SIDE: field depends on complete arrayBACK SIDE: field reduction depends on design

For your next review, provide ring radii, vector sequence, segment gaps, air gap and iron geometry. Compare working-side field and external field in the assembled model before changing the back iron or mechanical retention. This is a proposed evaluation workflow, not a performance claim.

Spoke: treat area concentration as a circuit question

The sketch illustrates adjacent tangential magnets feeding a common steel pole. A useful design review must include the working pole area, magnet area, hub and bridge paths and nonlinear steel data. This page has no specified pole width, steel curve or air gap, so concentration remains unknown.

Diagram 3: Spoke-Type Rotor Flux ConcentrationCircumferential magnetization driving flux into steel pole shoes
Laminated Rotor Pole (Fe)N →FOCUSED NORTH POLEAir Gap Flux Bg > Br← NLaminated Rotor Pole (Fe)Flux enters a common steel pole; gain needs a full model

Compare a model with actual bridges and shaft against an idealized model without those paths. Record where flux is diverted and whether local saturation changes the result. This comparison is a suggested method; no universal leakage percentage or steel saturation threshold is asserted.

Load line and temperature: why the checker leaves performance unknown

Remanence, intrinsic coercivity, curve shape and temperature are distinct inputs to magnet selection. A magnetic operating point depends on the circuit load line as well as the material curve. An arc-length-to-area ratio alone does not establish a thermal safety percentage. [S3]

Diagram 5: B-H Curve & Permeance Load LinesSchematic load lines; no orientation-specific Pc values
B (schematic)|H| (schematic)0Br (Remanence)HcBSteeper load lineExample operating point AShallower load lineExample operating point B
Table 4. Known versus unknown in this tool.
QuantityStatusMinimum additional evidence
Arc/chord/wall/end-face areaCalculated geometryDimensioned drawing and agreed tolerances for production
Requested Br and temperatureUser request onlySpecific grade and Br reference temperature
Permeance coefficient and fieldUnknown; not calculatedFull circuit, air gap, material curves and field model
Demagnetization marginUnknown; not calculatedGrade curves at temperature and worst reverse-field load case
Assembly force and retentionUnknown; not calculatedGap-dependent field/force model and structural load cases

Changing requested Br or temperature records a different inquiry requirement; it intentionally does not alter the geometric projections. The exporter preserves this distinction so an unknown magnetic rating cannot become a purchase specification.

Assembly and retention: define the missing load cases

Like-facing pole regions can repel; other relative orientations can attract. Peak force depends on position, gap and the surrounding array. The conceptual force arrows below are not force measurements. Do not select a jig, adhesive joint or retaining sleeve from Br and face area alone.

Diagram 6: Tangential Repulsion & Assembly Shear VectorsConceptual like-pole interaction; force depends on gap and array
Segment 1 (Fixed)NForce: model requiredNSegment 2 (Insertion)Rigid Non-Magnetic Mechanical Guide Fixture RequiredPrevents uncontrolled snap impact, edge chipping, and uneven adhesive displacement

Before a retention decision, request a review of speed, segment mass, radius, load path, thermal expansion, fit, fatigue and overspeed conditions. Adhesive selection also needs substrate, coating, surface preparation, bondline, cure and environment. This page supplies no universal speed threshold, sleeve thickness, preload or adhesive shear-strength matrix.

Agree an inspection plan with separate measurement targets

Diagram 8: Hall Probe Vector Field Inspection ProtocolsIllustrative component scan paths; acceptance to be agreed
Probe 1: End-Face B_theta ScanRecord tangential component and stand-offProbe 2: Radial Outer Surface B_rNormal component alone is insufficientQC: agree axes, scan path and acceptance limits
Table 5. Standards scope and proposed application measurements.
MeasurementReference / statusWhat must be agreed
Permanent-magnet material propertiesIEC 60404-5:2015 catalog scope [S4]Test conditions and required material properties
Magnetic dipole momentIEC 60404-14:2002 catalog scope [S5]Specimen, coil calibration, orientation and uncertainty
Local tangential/radial field scanApplication-specific planProbe axes, stand-off, grid, temperature and limits
Assembled waveform / harmonicsApplication-specific planRotor position, sensor setup, harmonic definition and limits

Part 5 concerns material measurements; Part 14 concerns dipole-moment measurement by withdrawal or rotation. Neither public catalog scope establishes a universal 1.5° vector-tilt criterion or a Hall-scan acceptance band. [S4] [S5]

For the illustrated application scan, record both the normal and tangential components at agreed positions. A normal-only reading cannot characterize the tangential vector; it also need not be zero. Archive raw readings and the fixture drawing alongside the agreed acceptance rules.

Three reproducible examples, not measured customer cases

All examples assume a uniform fixed chordal direction. They demonstrate only the equations above. There are no claimed dynamometer results, customer deployments or qualified material ratings.

Arc magnets magnetized through circumference checker with the default 52/44 mm arc geometry and ideal projection results
Software example captured 2026-11-07: OD 52 mm, ID 44 mm, span 22.5°, axial length 25 mm, 8 rotor poles, requested Br 1.42 T and 80°C; Halbach transition segment, sintered NdFeB. Mean arc 9.42 mm, outer chord 10.14 mm, radial wall 4.00 mm, end face 100.00 mm², maximum chordal error 11.25° and ideal mean projection reduction 0.64%. This is a reproducible software run, not a physical magnet test or customer case.

Narrow span

OD/ID 36/30 mm, span 25°, axial length 15 mm.

Mean arc 7.20 mm; tip direction error 12.5°; mean projection reduction 0.79%.

Compare the resulting local direction error with the drawing tolerance.

Moderate span

OD/ID 100/80 mm, span 45°, axial length 30 mm.

Mean arc 35.34 mm; tip direction error 22.5°; mean projection reduction 2.55%.

Model the circuit if field uniformity at the tips matters.

Wide span

OD/ID 100/80 mm, span 90°, axial length 30 mm.

Mean arc 70.69 mm; tip direction error 45°; mean projection reduction 9.97%.

Compare subdivision into smaller arcs, including extra joints and tolerances.

Enter these values in the checker

Sourcing: make the quote comparable

Use the exported brief as an inquiry draft. Attach a drawing revision and ask suppliers to distinguish machining, alignment tooling, magnetizing fixtures, coating, inspection and packaging. Request one-time and recurring costs separately, with quantity, validity date, prototype acceptance and lead-time assumptions.

Tooling cost, MOQ and delivery are unknown until quoted. A fixed chordal option and an assembly of smaller segments are alternatives to compare when custom orientation is unconfirmed. The lower projection error of smaller segments must be weighed against extra handling, joints and tolerance stack-up.

Risk and decision matrix

Table 6. Review priorities proposed for this workflow; no failure probabilities are assigned.
RiskDecision consequenceMinimum next action
Misuse: projection treated as efficiencyWrong motor target or misleading purchasing specificationKeep geometric results separate; validate the assembled field/torque model
Scenario mismatch: incompatible easy axisRequested vector pattern cannot be produced as drawnGet written orientation-process confirmation or compare segmented construction
Thermal assumption from material familyUnqualified grade or reverse-field operating pointObtain grade curves at temperature and analyze the actual load case
Cost: custom fixture omittedIncomplete unit-price comparison and scheduleRequest dated tooling, MOQ, inspection and prototype terms
Retention chosen from generic valuesUnverified mechanical assemblyReview actual forces, fit and thermal/mechanical load cases
Inspection axes or stand-off unspecifiedConflicting measurements and acceptance disputesApprove a common fixture and measurement procedure before production

FAQs for specification, validation and sourcing

Direction and geometry

What does magnetized through circumference mean?

The intended magnetization runs tangentially around an arc. Specify whether this means a continuously turning local direction, a fixed chordal direction, or a sequence of discrete vectors; the phrase alone is insufficient for manufacturing.

How does chordal parallel magnetization differ from curved alignment?

Chordal magnetization has one fixed direction parallel to the end-to-end chord. It matches the local tangent at the arc midpoint; direction error grows to half the arc span at each tip. Curved alignment follows the local tangent throughout.

Is the projection reduction a motor efficiency loss?

No. The mean reduction is 100 × [1 − sin(θ/2)/(θ/2)] with θ in radians. It averages a unit vector projection over the arc. Edge reduction is 100 × [1 − cos(θ/2)]. Neither includes the magnetic circuit, leakage, saturation or electrical losses.

Is there a universal maximum chordal arc angle?

No universal performance limit is established here. The tool uses 35° and 55° only as comparison bands. Use local direction tolerance and full-circuit field analysis to decide whether a larger span or several smaller segments meets the application.

Can a curved magnetizing fixture reorient any sintered magnet?

Do not assume it can. An anisotropic material has a preferred magnetic direction established in its processing. The supplier must confirm an easy-axis pattern compatible with the drawing; a different final magnetizing fixture alone does not establish that capability.

Are all bonded or ferrite magnets isotropic?

No. Material family alone does not identify the orientation. Specify the actual compound and whether it is isotropic or anisotropic, then confirm that its magnetization pattern and pulse fixture are compatible.

Array performance and testing

Can this tool predict Halbach flux gain?

No. Pole number, radii, magnet thickness, recoil permeability, segmentation, air gap and surrounding iron affect the complete array. The Halbach research linked in the report compares complete field models with FEA and measurements, rather than assigning a fixed gain to one arc.

What does a spoke flux concentrator require?

Tangentially magnetized pieces can feed a common steel pole. Evaluate magnet-face area, working pole area, bridge and hub leakage, steel B–H data and air gap in the complete rotor. This tool supplies geometry, not a concentration ratio.

Does rotor pole count mean number of magnet segments?

No. Rotor poles describe the full magnetic pattern. One pole may use multiple segments. State segments per pole, their orientation sequence, gaps and ring coverage separately in the drawing.

Why is no demagnetization safety percentage shown?

Temperature and material family do not determine a safety percentage. Grade-specific demagnetization curves at temperature and the worst reverse field are required. Br alone does not establish coercivity or irreversible loss.

How should circumferential magnetization be inspected?

Agree the probe axes, location, stand-off, scan path, temperature, calibration and acceptance limits with the supplier. A normal-component scan on the curved face alone does not characterize the tangential vector. Dipole moment and local surface field are different measurements.

What do IEC 60404-5 and IEC 60404-14 cover?

The cited 2015 edition of Part 5 addresses permanent-magnet material property measurements. The cited 2002 edition of Part 14 addresses magnetic dipole moment by withdrawal or rotation. These catalog scopes do not set a universal application-specific vector tilt or waveform acceptance limit.

Assembly and inquiry

Can I size an adhesive joint or retaining sleeve from this tool?

No. Required inputs include speed, radius, mass, load path, fit, thermal expansion, fatigue and verified joint properties. Request structural analysis and prototype validation before selecting adhesive, sleeve thickness or preload.

Are tooling prices, MOQ and lead time fixed?

No price or delivery commitment is established by this page. Ask the supplier to separate cutting, coating, alignment tooling, magnetizing fixtures, inspection and packaging in a dated quote tied to drawing revision and quantity.

What should I do if the geometry is unknown?

Use an illustrative preset to understand the fields, then send a drawing or application sketch through the contact link. Presets and worked examples are learning inputs, not qualified products or measured customer results.

What does the RFQ export include?

It includes requested dimensions, topology, material, Br and temperature plus explicitly idealized chordal comparisons. Unverified magnetic performance, tolerances, coating, retention, commercial terms and shipping classification remain open for agreement.

Review brief checklist and next action

  1. Confirm OD, ID, axial length, span, dimensional tolerances and reference view.
  2. Add local magnetization arrows, N/S markings, rotor poles, segments per pole and gaps.
  3. Request specific grade, Br reference temperature, thermal curves and application field review.
  4. Agree local scan and/or dipole-moment acceptance, coating, retention and handling requirements.
  5. Add drawing revision, quantity, sample acceptance, dated commercial terms and shipping review.

If dimensions are missing, send an application sketch for review. For the distinct task of interpreting a field profile, see the circumferential magnetic-field guide or field-diagram reference.

Sources, method and limits

Sources checked 2026-11-07. Publication years below describe the cited editions, not a claim that every standard is the latest contractual edition. Agree the applicable edition and licensed test method with your laboratory. Equations, comparison bands, worked examples and review checklists are this page’s own geometry derivations or proposed workflow, as identified above.

  1. [S1] Xia, Zhu & Howe (2004), Analytical Magnetic Field Analysis of Halbach Magnetized Permanent-Magnet Machines

    IEEE Transactions on Magnetics 40, 1864–1872. DOI: 10.1109/TMAG.2004.828933. Complete-machine field models, FEA and measurements; not a fixed segment gain.

  2. [S2] Arnold Magnetic Technologies, The Elements of Magnetics (2013)

    Background on preferred magnetization directions and material processing. Does not establish custom curved-alignment capability for a supplier.

  3. [S3] Arnold Magnetic Technologies, Magnet FAQs (2013)

    Br, coercivity, temperature and load-line concepts. Not qualification of these presets or an adhesive/retention specification.

  4. [S4] IEC 60404-5:2015 — permanent-magnet material measurement methods

    Public catalog scope: material properties and demagnetization curves. This page does not claim access to all normative clauses or prescribe standard acceptance limits.

  5. [S5] IEC 60404-14:2002 — magnetic dipole moment measurement

    Public catalog scope: withdrawal or rotation with a detection coil. Does not certify a local surface Hall scan or an automotive vector-tilt tolerance.

  6. [S6] K&J Magnetics, Magnetization Directions — Arc Segments

    Undated supplier documentation, checked 2026-11-07. The circumferential catalog label describes parallel directions, not vectors curving around the arc. No capability or stock claim for EVMotorMagnets follows.

Use this page for geometry comparison and preparing a review brief. Magnetic performance, thermal margin, mechanical retention and manufacturing capability remain unqualified until the complete application is modeled and tested. No measured customer cases, adhesive properties, supplier prices or delivery commitments are established here.

Ready to discuss a drawing?

Include geometry, orientation arrows, application, grade requirements and quantity. Ask for feasibility and a dated quote.

Request drawing review